Approx. Rs 6,500 / PieceGet Latest Price

Product Details:
TypeSemi-Automatic
Digit Display SizeSingle
Dimensions40 X 14 X 10 Cm
Load30 A
Operating Temperature RangeMinimum -40 to Maximum 60 degree Celcius
Rated Voltage12V/24V/36V/48V/60V

Specifications:

  • Dimensions: 40 X 14 X 10 Cm
  • Operating Temperature Range: Minimum -40° to Maximum 60° C
  • Rated Voltage: 12V/24V/36V/48V/60V
  • Nominal Battery Voltages: 12, 24, 36, 48, 60 VDC Combine in One, Automatic
Yes! I am interested

Synchronous Firing Power Controller

REQUEST CALLBACK

Synchronous Firing Power Controller
Get Best Quote

Thanks for Contacting Us.

Approx. Rs 4,500 / UnitGet Latest Price

Product Details:
TypeAutomatic
Leak Current5 mA or less
AC VoltageAC100 - 220V
Input Impedance540 ohm
Load Current5A, 10A, 20A, 40A
Input Signal4-20mA DC

This is also commonly known as zero cross over firing or burst firing method. In this technique, we trigger the scr at the moment sine wave crosses zero and the anode is driven positive, the power control is achieved by having the scrs on for some cycles and off for other cycles. The ratio of no. Of cycles on to no. of cycles off is varied to proportional the power delivered to the load.
Yes! I am interested

Phase Angle Firing Power Controller

REQUEST CALLBACK

Phase Angle Firing Power Controller
Get Best Quote

Thanks for Contacting Us.

Approx. Rs 4,500 / UnitGet Latest Price

Product Details:
TypeAutomatic
Load Current5A, 10A, 20A
AC VoltageAC100 - 220V
Input Impedance540 ohm
Input Signal4-20mA DC
Connection2 Wire Connection, Star, Delta Connections

In this method, the thyristor is triggered in every cycle. Basically, we are delaying the SCR gating until some time after the voltage crosses the zero, by varying this delay (measured in electrical degrees) in turn we are controlling the conduction i.e. the on time, and as such the power output to the load is controlled.

There are certain applications which require continuous proportional power. Even certain heating elements require only phase angle type power controller, namely silicon carbide, super central, infrared heaters and transformer coupled heaters.
Yes! I am interested

 
X


Explore More Products

Contact via E-mail
Contact via SMS
MIFA Systems Private Limited
Joy DSouza (Sales Manager)
No. 702, AKIK, Opposite Rajpath Club Sarkhej-Gandhinagar Highway, Bodakdev,
Ahmedabad - 380015, Gujarat, India
Call Us: 
Call Response Rate: 78%
Share Us :
F G T L



Home  |   Profile   |  Products & Services  |  Site Map  |   Contact Us

© MIFA Systems Private Limited. All Rights Reserved (Terms of Use)
Developed and Managed by IndiaMART InterMESH Limited

MIFA Systems Private Limited